Skip to content
Back to search results

EXAFS

Introduced by
Edward Stern
Year
1971
Type
Synchrotron technique
Family
X-ray Spectroscopy
Font size

What does it do?

Extended X-ray Absorption Fine Structure (EXAFS) is a synchrotron-based X-ray spectroscopy technique that measures the local geometric and electronic structure around a specific atom in any material, crystal or amorphous.

Discovered by Sayers, Stern, and Lytle in 1971, EXAFS reveals interatomic distances, coordination numbers, and disorder in the atomic environment by analyzing oscillations in the X-ray absorption spectrum above an absorption edge.

The intuition behind the method

When an X-ray photon is absorbed by a core electron of an atom, the photoelectron's outgoing wave is scattered by neighboring atoms. These scattered waves interfere with the outgoing wave, creating oscillations (wiggles) in the X-ray absorption coefficient above the absorption edge. The frequency and amplitude of these oscillations depend on the distances, coordination numbers, and types of neighboring atoms. By analyzing the oscillations, one extracts a radial distribution function showing how many atoms are at each distance from the central atom.

History

Sayers, Stern, and Lytle developed EXAFS in the early 1970s using early synchrotron sources. The technique was initially used to study disordered materials and catalysts where crystallography failed. Recognition of EXAFS's power came in the 1980s-1990s as third-generation synchrotrons provided brilliant X-ray beams. EXAFS became routine for catalyst characterization, metallurgy, and environmental science. Refinements including polarization-dependent EXAFS and high-resolution EXAFS (HR-EXAFS) extended the technique's reach.

When to use it

Apply EXAFS to determine local atomic structure in materials where long-range crystallinity is absent or unimportant: amorphous catalysts, glasses, disordered alloys, and metal sites in proteins and enzymes. EXAFS is element-selective and probes the first and second coordination spheres. Requires access to a synchrotron beamline.

Limitations and considerations

  • Requires synchrotron radiation; beamline access is limited and expensive
  • Low-Z elements (< Ca): EXAFS signals weaker; technique less sensitive for light atoms
  • Interpretation ambiguous when similar atoms occupy nearby sites
  • Multiple scattering at high energies complicates analysis for heavy atoms and extended distances

Source conditions do not replace independent scientific review or validation by an analysis engine.

Strengths

  • Element-specific: selects one atom type, avoiding interference from other elements
  • No crystallinity required: works equally well for crystals, glasses, and amorphous materials
  • Coordination geometry revealed: distances and coordination numbers extracted from a single scan
  • Local structure information: probes 1-3 Ångströms around the absorbing atom

Applications

  • Catalyst structure determination: revealing the local coordination of metal sites in heterogeneous catalysts during in situ operation
  • Metallurgy and materials science: determining short-range order in alloys and amorphous metals
  • Geochemistry and environmental science: measuring coordination environments of trace metals (As, Pb, Hg) in soil and aquifer samples
  • Biochemistry: elucidating metal site geometry in metalloproteins (copper oxidases, iron-sulfur clusters) without crystallization

How it works

How it works

1

A beam of tunable synchrotron X-rays is directed at the sample; X-ray absorption is measured as a function of photon energy across and above an absorption edge.

2

The smooth background absorption is modeled and subtracted, leaving only the fine structure oscillations above the edge.

3

The oscillations are converted to k-space (wavenumber) and Fourier-transformed to give a radial distribution function.

4

Theoretical predictions for different atomic configurations are fit to the experimental data.

5

Fitting yields coordination numbers, interatomic distances, and disorder parameters around the central atom.

Common pitfalls

  • Over-interpreting EXAFS coordination numbers without x-ray diffraction or transmission electron microscopy confirmation
  • Neglecting thermal disorder effects, which broaden peaks and reduce amplitude
  • Comparing EXAFS-derived structures to crystallographic data without accounting for different timescales (EXAFS time-averaged, crystals static)

Frequently asked questions

What is the difference between EXAFS and XANES?

XANES (X-ray Absorption Near Edge Structure) probes the region within ~50 eV of the absorption edge and reveals oxidation state and local symmetry. EXAFS probes 50-1000 eV above the edge and reveals atomic distances and coordination numbers. XANES has lower spatial resolution but is faster to measure.

How does EXAFS determine coordination number?

The amplitude of oscillations in EXAFS is proportional to the number of scattering atoms at a given distance. Fitting theoretical models to the data yields the coordination number (number of neighbors) at each distance shell.

Can EXAFS distinguish between different atoms at the same distance?

Not perfectly, but elements with different atomic numbers scatter X-rays with different strengths and phase shifts. With careful analysis and comparison to reference compounds, one can partially distinguish neighboring atom types. X-ray diffraction provides definitive element identification.

Related methods

Sources

  1. Sayers, D. E., Stern, E. A., & Lytle, F. W. (1971). New technique for investigating noncrystalline structures: Fourier analysis of the extended X-ray absorption fine structure. Physical Review Letters, 27(18), 1204-1207.

    Open DOI reference
    Copied.
  2. Stern, E. A., Sayers, D. E., & Lytle, F. W. (1975). Extended x-ray-absorption-fine-structure technique. Physical Review B, 11(12), 4836-4846.

    Open DOI reference
    Copied.