Electrical Resistivity Tomography
- Introduced by
- Loke and Barker
- Year
- 1996
- Type
- Active source resistivity mapping and subsurface imaging
- Family
- Electromagnetic inversion
What does it do?
Electrical Resistivity Tomography (ERT) is an active-source geophysical method that maps the spatial distribution of electrical resistivity in the subsurface by injecting current between two electrodes and measuring potential differences across an array of receiver electrodes.
Advanced as a practical technique by Loke and Barker in 1996, ERT has become standard for hydrogeological, environmental, and structural characterization due to its sensitivity to fluid saturation and salt content.
The intuition behind the method
ERT works by injecting electrical current into the ground through a pair of current electrodes and measuring the resulting potential differences at many receiver locations. Rocks with higher water content and dissolved minerals conduct current more easily (lower resistivity), while dry or fresh rocks are more resistive. By systematically varying the injection and measurement electrode pairs—collecting hundreds or thousands of measurements—a 2D or 3D model of subsurface resistivity is reconstructed via inversion. Resistivity variations map fluid saturation, lithology, and contamination.
History
Electrical prospecting methods date to the early 20th century, but modern ERT emerged in the 1990s with the advent of multi-electrode systems and digital data acquisition. Loke and Barker's 1996 inversion algorithm (RES2DINV) transformed ERT from a research tool to an industry standard. The 2000s saw rapid adoption in environmental and hydrogeological consulting. Recent developments include time-lapse (4D) ERT for monitoring contaminant plumes, borehole-to-surface ERT for extended depth range, and machine-learning inversion algorithms.
When to use it
ERT is excellent for detecting groundwater saturation, mapping aquifer boundaries, and monitoring contaminant transport in environmental investigations. It is also useful for landslide hazard assessment, cavity detection, and geotechnical site characterization. Resistivity contrasts must be sufficient (typically >2:1) for ERT to resolve features. Combine ERT with seismic or borehole data for multi-parameter interpretation.
Limitations and considerations
- Sensitivity decreases with depth; deeper structures require longer electrode spacings but lose lateral resolution
- Interpretation is non-unique; different resistivity distributions can produce nearly identical data
- High-conductivity surface layers (wet clay, salt) attenuate signals and obscure deeper structures
- Inversion algorithms are computationally demanding for large 3D datasets and may require damping to remain stable
Source conditions do not replace independent scientific review or validation by an analysis engine.
Strengths
- Excellent sensitivity to fluid saturation and ionic content, directly reflecting hydrogeological and contaminant conditions
- Flexible array geometries and electrode spacing allow targeting of specific depth ranges
- Can be deployed on surface, in boreholes, or in mines for flexible 2D/3D investigations
- High data density (hundreds to thousands of measurements) enable detailed spatial resolution
Applications
- Groundwater and contaminant monitoring: mapping saltwater intrusion fronts, tracking landfill leachate plumes, delineating contaminated zones in soil and aquifers
- Landslide and geotechnical assessment: identifying zones of altered resistivity related to landslide failure surfaces or unstable soil layers
- Geothermal resource characterization: mapping areas of elevated temperature and alteration minerals associated with geothermal reservoirs
- Archaeological surveys: detecting buried structures, fill patterns, and subsurface voids in cultural resource investigations
How it works
How it works
A multi-electrode cable is planted on the surface or in boreholes. Current is injected between pairs of electrodes, and potential voltages are recorded at many other electrode pairs. Multiple current-injection schemes (Wenner, Schlumberger, dipole-dipole) are used sequentially to acquire redundant data.
Apparent resistivity values are calculated from the injected current and measured potential difference using geometric factors specific to the electrode configuration. Reciprocal measurements and data quality checks are performed to identify and remove erroneous readings.
A starting resistivity model is created based on the mean apparent resistivity. Theoretical apparent resistivity values are computed from this model using numerical methods (finite element or finite difference).
An iterative inversion algorithm (damped least squares, smoothness-constrained) adjusts the resistivity model to minimize the difference between measured and predicted data. Iterations continue until convergence or a stopping criterion is met.
The final inverted resistivity section is calibrated against boreholes, known lithology, and hydrogeological data. Resistivity anomalies are interpreted as fluid saturation zones, contaminant plumes, bedrock surfaces, or structural features.
Common pitfalls
- Misidentifying surface contamination or salt layers as deep hydrogeological features without depth constraints
- Using poorly conditioned electrode arrays (too wide, too narrow) that lead to insensitive data and poor inversions
- Over-interpreting fine-scale resistivity anomalies that are artifacts of inversion damping rather than true subsurface features
Frequently asked questions
What is the difference between ERT and traditional vertical electrical sounding (VES)?
VES injects current at one pair of locations and measures potential at progressively larger electrode spacings, creating a 1D resistivity profile at one horizontal location. ERT uses fixed electrode arrays with multiple current injections and dense measurements, creating 2D or 3D resistivity distributions. ERT provides lateral structure; VES provides depth detail at a single point.
How deep can ERT investigate?
Approximate maximum depth is one-quarter to one-third of the total electrode array length. For a 100 m array, expect reliable imaging to 25–33 m. Achieving greater depth requires longer arrays, which increases survey time and cost. Borehole-based ERT can image deeper structures with shorter surface arrays.
How long does an ERT survey take?
Survey time depends on array length, number of electrodes, and the inversion software. A 1D sounding with 10–15 electrode spacings takes 30 minutes to 1 hour. A 2D profile with 48–64 electrodes can take 1–3 hours. 3D surveys can require many hours to days depending on spatial coverage and measurement density.
What electrode spacing should I use?
Electrode spacing is chosen based on the target depth and lateral resolution required. Smaller spacing (<1 m) resolves shallow features; larger spacing (>5 m) targets deeper structures but with reduced lateral resolution. Common spacings for hydrogeological investigations range from 2–10 m.
Related methods
Sources
Loke, M. H., & Barker, R. D. (1996). Rapid least-squares inversion of apparent resistivity pseudosections by a quasi-Newton method. Geophysical Prospecting, 44(1), 131-152.
Open DOI referenceCopied.Telford, W. M., Geldart, L. P., & Sheriff, R. E. (1990). Applied geophysics (2nd ed.). Cambridge University Press.